Re: Bizhub C250?
Отключение чипов-счетчиков
1. Press the Utility/Counter key.
2. Touch [Details] on [Meter Count].
3. Press the following keys in this order.
Stop → 0 → 0 → Stop → 0 → 1
далее для разных аппаратов:
C350:
Setting 1 – Tech Rep – System Input / Unit Change – Set Image unit to Service
Setting 2 – Tech Rep – “Stop 9”, then “IU LIFE STOP SETTING” – set to No Stop
C250 / C252 / C300 / C352 and C351 / C450
Setting 1 – Tech Rep – System 2 / Unit Change – Set Image unit to Service
Setting 2 – Tech Rep – “Stop 0 C”, then “IU LIFE STOP SETTING” – set to No Stop
__________________
www.pro-delta.ru
Полиграфическое оборудование б.у. Поставка и Сервис.
(495)923-4413
|