но потом начал в конце своего теста выдавать ошибку 0001001b.
During printing operation, there may be a case where the temperature inside the
print head has risen above the specified value and the thermistor in the print head
detects it as abnormal temperature. In such a case, this message is displayed and
the printer stops operating.
��
Cause of trouble:
•
Head broken down.
•
Faulty contact of tape electric wire, broken wire or wire out of position.
После замены начал грузиться и выдал ошибку 0001000с.
Explanation:
During initial operation at power on or during head platen gap fluctuation (change)
operation after paper setting, there may be a case where the head slide home
position can not be detected. In such a case, this message is displayed and the
printer stops operating.
��
Cause of trouble:
•
Home position detection error due to head slide out-of-step
•
Defective head slide home position sensor
•
Defective head slide motor, disconnected connector or broken cable
•
Gears not engaged properly
��
Points to be checked:
��
Head Slide Detection Sensor
•
Check that the sensor functions properly.
•
Check that the sensor and the head platen gap drive gear are free from
obstruction by adhesion of foreign matters or soiling.
��
Head Slide Motor (Pump Motor)
•
Measure the resistance value. (9.2Ω)
If the motor is found in short mode, replace the C472MAIN Board at the same
time.
•
Check that the motor operates properly.
(Refer to “5.2.2.4 Encoder ”(p224) in the self-diagnostics menu.)
•
Check that the gear train including the head platen gap drive gear is free from
any obstruction.
Думаю, это максимум, чем вам могут помочь, в том числе в сервисе.