X Регистрация |
Здравствуйте! Для размещения своих сообщений на форуме предлагаем зарегистрироваться. |
![]() |
![]() |
![]() |
![]() |
#3 |
Модератор
|
![]()
C3451 Heating Roller warm-up failure
• The temperature of the Heating Roller does not reach 100 °C within 50 sec. after the Heating Roller Heater Lamp has been turned ON. • The temperature of the Heating Roller does not reach 100 °C and that of the Fusing Pressure Roller does not reach 195 °C within 200 sec. after the Heating Roller Heater Lamp has been turned ON. • The voltage of the Heating Roller Thermistor does not increase by five steps within 20 sec. after the Heating Roller Heater Lamp has been turned ON. • No zero cross signal is detected even with the lapse of 1 sec. or more after the Heating Roller Heater Lamp has been turned ON. |
![]() |
![]() |